== Nexus 4000 ==
 * MTBF [[http://www.cisco.com/en/US/prod/collateral/switches/ps9441/ps10596/ps10642/data_sheet_c78-560881_ps10596_Products_Data_Sheet.html|187,265 hours]] = 21years.
   *
== vPC ==
 * [[http://bradhedlund.com/2010/12/16/routing-over-nexus-7000-vpc-peer-link-yes-and-no/|Rules and diagrams]]
 * Check witch link in a port channel will be used.
 * show port-channel load-balance forwarding-path interface port-channel 2 vlan 902 dst-ip 192.168.110.212 src-ip 192.168.110.200
# sh hardware internal carmel port e 1/1
 * QOS http://alleasysetup.blogspot.com/2011/10/qos-on-cisco-nexus-5k.html
 * FlowControll to VMware http://www.boche.net/blog/index.php/2010/11/29/flow-control/
 * vPC virtual port channel, let port's on 2 vPC peers look like they are from one switch, eliminating blocked ports on ethertrunk.
 * Step1 enable features needed on switches.
   {{{
   feature lacp
   feature vpc
   }}}
 * peer-gateway - only for dumb hosts that do not use arp for gw discovery, but incoming packet.
 * pinning max-links 1
 * Before the peer link will come up, you also have to set up VPC keepalives to detect dual active peers
  {{{
  vpc domain 1
    peer-keepalive destination 10.10.10.14 source 10.10.10.13
  }}}
 * VPC Rule 101
   * VPC peers are expected to forward a frame received on a member link out any other member link that needs to be used. Only if they cannot do so due to a link failure, is forwarding across the VPC peer link and then out a member link allowed, and even then, the cross-peer-link traffic can only go out the member link that is paired with the member link that is down.

 * Restatement of VPC Rule 101
   * To put it another way, VPC peers are expected to forward a frame received on a member link out any other member link that needs to be used. Only if they cannot do so due to a link failure, is forwarding across the VPC peer link and then out a member link allowed, and even then, the cross-peer-link traffic can only go out the member link that is paired with the member link that is down.

 * With VPC, one should always put keepalives on a different link than the VPC peer link, since their purpose is to detect a situation with the peer still up but VPC peer link down. You just can't do that if they're running over the peer link. Instead, you can use the management port. Or, if you put a separate point-to-point routed link between the peers, in parallel with the VPC peer-link, you can use that for the keepalives.

  * The L3 decision determines the outbound interface. If that outbound link is a VPC member link, the same forwarding rule is applied as for L2: the frame (packet) came in the peer-link, the member interface that is VPC-paired to the chosen outbound link is up, therefore drop the packet.
 
 * Check fiber signal strength.
   {{{
   sh interface transceiver details
   }}}
Line 5: Line 44:
   *  3064 - 1RU - L2 & L3 10Gbit/s on 64 ports 48-SFP+ + 4 x QSFP+ (40Gbit or 4 x 10Gbit )    * 3064 48 x 10G + 4 x 40G - 1RU - L2 & L3 10Gbit/s on 64 ports 48-SFP+ + 4 x QSFP+ (40Gbit or 4 x 10Gbit )
   * 3016 16 x 40G quad sfp ports.
Line 14: Line 54:
 * [[http://www.cisco.com/en/US/docs/switches/datacenter/nexus2000/sw/configuration/guide/rel_4_1/Cisco_Nexus_2000_Series_Fabric_Extender_Software_Configuration_Guide_chapter3.html|Nexus 2000]] config, upgrade, dualhome
 *
 * [[http://www.cisco.com/en/US/docs/switches/datacenter/nexus2000/sw/configuration/guide/rel_4_1/Cisco_Nexus_2000_Series_Fabric_Extender_Software_Configuration_Guide_chapter3.html|Nexus 2000]] config, upgrade, dual-home



Cisco Nexus

Nexus 4000

vPC

  • Rules and diagrams

  • Check witch link in a port channel will be used.
  • show port-channel load-balance forwarding-path interface port-channel 2 vlan 902 dst-ip 192.168.110.212 src-ip 192.168.110.200

# sh hardware internal carmel port e 1/1

  • QOS http://alleasysetup.blogspot.com/2011/10/qos-on-cisco-nexus-5k.html

  • FlowControll to VMware http://www.boche.net/blog/index.php/2010/11/29/flow-control/

  • vPC virtual port channel, let port's on 2 vPC peers look like they are from one switch, eliminating blocked ports on ethertrunk.
  • Step1 enable features needed on switches.
    •    feature lacp
         feature vpc
  • peer-gateway - only for dumb hosts that do not use arp for gw discovery, but incoming packet.
  • pinning max-links 1
  • Before the peer link will come up, you also have to set up VPC keepalives to detect dual active peers
    •   vpc domain 1
          peer-keepalive destination 10.10.10.14 source 10.10.10.13
  • VPC Rule 101
    • VPC peers are expected to forward a frame received on a member link out any other member link that needs to be used. Only if they cannot do so due to a link failure, is forwarding across the VPC peer link and then out a member link allowed, and even then, the cross-peer-link traffic can only go out the member link that is paired with the member link that is down.
  • Restatement of VPC Rule 101
    • To put it another way, VPC peers are expected to forward a frame received on a member link out any other member link that needs to be used. Only if they cannot do so due to a link failure, is forwarding across the VPC peer link and then out a member link allowed, and even then, the cross-peer-link traffic can only go out the member link that is paired with the member link that is down.
  • With VPC, one should always put keepalives on a different link than the VPC peer link, since their purpose is to detect a situation with the peer still up but VPC peer link down. You just can't do that if they're running over the peer link. Instead, you can use the management port. Or, if you put a separate point-to-point routed link between the peers, in parallel with the VPC peer-link, you can use that for the keepalives.
    • The L3 decision determines the outbound interface. If that outbound link is a VPC member link, the same forwarding rule is applied as for L2: the frame (packet) came in the peer-link, the member interface that is VPC-paired to the chosen outbound link is up, therefore drop the packet.
  • Check fiber signal strength.
    •    sh interface transceiver details
  • Other options
  • Nexus 3000 Ultra Low Latency

    • 3064 48 x 10G + 4 x 40G - 1RU - L2 & L3 10Gbit/s on 64 ports 48-SFP+ + 4 x QSFP+ (40Gbit or 4 x 10Gbit )

    • 3016 16 x 40G quad sfp ports.
  • Cisco Nexus 5548P Switch Oct 2010

    • Need SPS license for FC.
    • L3 capable. additional hardware

    • Nexus2k Fabric extender
      • 2148T
      • 2248TP GE
      • 2231PP 10GE
  • Nexus 2000 config, upgrade, dual-home